| Properties |
Limits |
Appropriate Standards |
| Operating Temperature |
–40°C to +85°C |
MIL-STD-810E |
| Storage Temperature |
–40°C to +85°C |
|
| EMC |
With MIL-C-38999 connectors fitted |
MIL-STD-461D
DEF.STAN 59-41
BS3G100
TEMPEST |
| Power Inputs |
28V DC
115V / 400 Hz Single-Phase
115V / 400 Hz Three-Phase |
MIL-STD-704A and -704E
MIL-STD-1275A
DEF.STAN 61-5 (Naval)
MIL-STD-1399 (Naval)
EN50155 / RIA12 (Railway)
|
| Wiring |
Limited Toxicity |
MIL-C-24643
DEF.STAN 61-12 Part 18
DEF.STAN 66-31 |
| Mechanical |
–40°C to +85°C |
Arinc 404A |
| IP Rating |
With MIL-C-38999 connectors fitted |
Direct cooling up to IP65
Indirect cooling up to IP53 |
| Vibration |
15 to 2,000 Hz at 0.1g2 / Hz (RMS ~ 12g) |
MIL-STD-810E
Method 514.4 Category 5
MIL-STD-167
DEF.STAN 66-31 |
| Shock |
20g for 11mS |
MIL-STD-810E
Method 516.4 Proc I & VI |
| Acceleration |
13.5g |
MIL-STD-810E
Method 513.4 Proc I & II |
| Altitude |
10,000 ft standard chassis
50,000 ft with high altitude fan
|
MIL-STD-810E |
| Humidity |
Up to 95% RH |
MIL-STD-810E
Method 507.3 Procedure III |
| Salt Fog |
5% for 48 Hours |
MIL-STD-810E
Method 509.3 |
| Fungal Growth |
No Growth |
MIL-STD-810E
Method 508.4 |
| Thermal Shock |
Rapid change over Storage & Operational Temperature range |
MIL-STD-810E
Method 503.3 Procedure I |
| Sand & Dust |
Sand @ 95 ft /sec (29m/sec)
Dust @ 29 ft /sec (8.9m/sec) |
MIL-STD-810E
Method dependant on filter material |
| Epoxy Paint Finish |
Resistant to contaminants |
MIL-C-22750F
DTD-5555A |